Morphometric study of percutaneous A1 pulley of thumb release. Scientific reports Through anatomy, microscope, histopathology, and simulating needle knife operation on specimens, to accumulate the relevant parameters of the A1 pulley of thumb, and to provide an anatomical evidence for the needle knife therapy of stenosing flexor tenosynovitis. A total of 20 fingers were selected from 20 intact adult upper limb specimens, a small amount of emerald green waterproof dye was injected from the needle insertion point, dissected layer by layer, and the A1 pulley and neurovascular bundle were observed. Observe the loosening of the thumb A1 pulley after 5 and 10 times of simulated needle knife cutting on the specimen; observe the relationship between the needle knife entry point and the A1 pulley under the thumb extension and abduction, and the thumb extension neutral position respectively; further observe the histological characteristics, and the relationship between needle entry point and A1 pulley by microscope. ① In general observation, the A1 pulleys of each finger were transverse fibers perpendicular to the flexor tendon, tough in texture, connected with synovial fibers at the proximal end. It is difficult to distinguish, and connected with oblique fibers at the distal end. ② The release rate of the thumb A1 pulley after 5 and 10 times of simulated needle knife cutting on the specimen were (40.46 ± 2.22)% and (63.52 ± 4.49)%, respectively. ③ In the neutral position of the thumb straightening, the needle entry point is 3.06 ± 0.14 mm from the proximal side of the proximal edge of the A1 pulley, which overlaps with the needle entry point where the thumb is straight and abducted. ④ Observed under a microscope, the A1 pulley is a dense transverse fiber with a pale yellow dense connective tissue, both ends are continuous with the synovial fibers. It is thin and translucent, and loose connective tissue. The A1 pulley is a dense transverse fiber with a pale yellow dense connective tissue. The anatomical key points of the needle knife therapy lie in the extended and abducted position of the thumb. Currently, it is believed that cutting the proximal edge of the A1 pulley is sufficient, and there is no need to cut the entire A1 pulley. 10.1038/s41598-022-24759-5
[Ultrasound-guided needle-knife for trigger finger]. Zhang Wen-Bing,Yao Dong-Wen,Wu Wei-Xian Zhongguo zhen jiu = Chinese acupuncture & moxibustion OBJECTIVE:To explore the efficacy of ultrasound-guided needle-knife with precise three-dimensional stereotactic localization of points for stenosing tenosynovitis of flexor tendon (trigger finger). METHODS:A total of 74 patients were randomly divided into an observation group and a control group, 37 cases in each group. The patients in the observation group were treated with ultrasound-guided intrathecal injection and releasing method of needle-knife, while the patients in the control group were treated with ultrasound-guided intrathecal injection. The self-made 9-score scale of trigger finger was recorded before treatment, immediately after treatment, 1 month and 3 months after treatment; the curative effect of the two groups was evaluated. RESULTS:The results of self-made 9-score scale in the observation group immediately after treatment, 1 month and 3 months after treatment were lower than that before treatment (all <0.01); the scores in the observation group were lower than those in the control group at each time point after treatment (all <0.01). The excellent and good rate immediately after treatment was 100.0% (37/37) in the observation group, which was superior to 8.1% (3/37) in the control group (<0.05); the cured rates in the observation group were 100.0% (37/37) 1 month after treatment and 97.3% (36/37) 3 months after treatment, which were superior to 13.5% (5/37) and 10.8% (4/37) in the control group, respectively (<0.05). CONCLUSION:The needle-knife with three-dimensional stereotaxic location of point could significantly improve the symptoms of trigger finger, with superior immediate and long-term efficacy. 10.13703/j.0255-2930.2019.08.017